Modifications to the design of our contactors, covers, auxiliary switches, and mechanical interlocks have been made to support compliance with UL standard 60335-2-40 pertaining to A2L refrigerants.
Electronic Interface Functionality On CA9 Contactors
What is the ‘ EI ‘ electronic interface function? And – how does it work on the CA9 contactors?
Are there options to use / or not use the ‘ EI ‘ electronic interface functionality on the CA9 contactor?
Chatter, humming or buzzing coming from a contactor indicates a problem and should be investigated. Here are three common issues that could cause unexpected noises from an installed contactor.
CA6-420, CA6-630 Or CA6-860 Contactors With 24V Or 48V AC Or DC Coils
Is there 24V or 48V AC or DC coil option for the 420, 630 or 860 amperage CA6 contactors?
There are no 24V or 48V AC or DC coil options available for the CA6-420, CA6-630 or CA6-860 contactors but the built in electronic interface offers an alternative.
Is there an instruction sheet for the CA6-AT1, CA6-AT2 and CA6-AT3 Control Terminals? What is the purpose of these terminals? Can they be used as control circuit taps using other contacts? What are the mounting hole and wire sizes for CA6-AT terminals?
What are the distinctions between CAS7 Safety Contactors and CSS7 Relays versus General Purpose CA7 Contactors and CS7 Relays? Does the CA7/CA6 Contactor or CS7 Relay have safety ratings?
Is there a dimensional comparison of CA7 or CAN7 contactors with AC coils and contactors with Electronic DC coils? Are they the same size? The answer depends on the control voltage used for the electronic DC coil.
The small plastic latches that secure the auxiliary to the contactor can easily snap off when applying too much force. There are three easy steps for removing the auxiliary.
Maximum Number Of Terminal Wires On CA7 Contactors
Series CA7 contactors in amperages 9 thru 23 have built-in auxiliary contacts. A circuit designer might need to reference these terminals on an assembly drawing.
Terminal Markings On Built In CA7 Contactor Auxiliaries
How long is the real service life on a contactor under standard operating conditions? To determine this you need to know the rated electrical life, and the total number of operations expected out of the contactor.
Definite Purpose (DP) Versus General Purpose (IEC) Contactors
How do you compare and cross reference a definite purpose contactor to an IEC general purpose contactor? Cross referencing a definite purpose contactor to an IEC contactor involves analysis of the application, not just a amps to amps comparison.
What Are Some Possible Reasons For Welded Contacts?
When a contactor is cycled too fast the silver alloy of the contact tips will heat up and become molten and then tack-weld on the next closing, which renders the contactor inoperative. So, the question becomes: what issues in the control circuit can cause excess cycling of the contactor?
How To Determine Coil Resistance Of CA7 AC Or DC Contactors
What is the resistance on my contactor coil? With an Ohm meter, the contactor coil resistance can be measured using the A1-A2 terminals of the coil. But how do you know if the measurement is correct?
The use of electronic DC contactors and control relays can reduce the size requirements of DC power supplies. The CRI7E external electronic interface is another way to reduce DC power requirements.
Some technical specifications can be difficult to decipher. How do you read the vibration specifications for CA7 contactors and what do the specifications actually mean?
Undersized Power Supplies Can Cause DC Contactor Coil Failures
Customers often select a marginally sized 24VDC power supply to offset costs compared to a CCT. This often leads to DC contactor coil failure and costly downtime. The standard features of improperly sized power supplies can inflict disaster on the contactor coils they are operating.
About 85% of all coil burn-outs are caused by low voltage resulting from insufficient control power. Field personnel can identify possible causes and prevent the death of contactor and/or relay coils.
A combination of many factors can affect the dependability, life expectancy, and suitability of an auxiliary contact block in any given application. Understanding the most important of those factors can help you select the best switch for your needs.