Loading
Back to
View All
  • Products
    • ALL PRODUCTS
      • Contactors
      • Overload Protection
      • Starters + Enclosed Product
      • Motor Controllers + MCCBs
      • Softstarters
      • Circuit Protection
      • Disconnect Switches
      • Rotary Cam Switches
      • Control + Timing Relays
      • Pilot Devices
      • Signaling Devices
      • Terminals
      • Power Supplies
    • Custom Control Panels
      • Capabilities
      • Combination Starters
      • Explosion Proof
      • Multi-Speed and Reduced Voltage
  • Library
    • LIBRARY
      • Product Catalog
      • Literature
      • Cross Reference
      • Technical Tips & FAQs
      • CAD Drawings
      • Wiring Diagrams
    • APPROVALS
      • UL/CSA Documents
      • CE-DOC
      • Atex
      • CCC
      • RCM/TUV/ABS/RINA
      • ISO9001
      • SUVA Certificates
      • Functional Safety Data
      • Environmental Compliance
  • Company
    • COMPANY
      • About Sprecher + Schuh
      • Contact Us
      • Industries Served
      • Success Stories
      • Terms & Conditions
      • Privacy Policy
      • Technical Support
      • International
  • Sales
    • SALES
      • Find a Reseller or Sales Rep
      • Become a Distributor
      • B2B Portal
    • CONTACT US
      • United States
      • Canada
      • International
  • Support
    • SUPPORT
      • Technical Support
      • Technical Tips & FAQs
      • Find a Reseller or Sales Rep
      • Contact Us
      • B2B Portal
Tech Tips
    • Contactors
    • Contactors
    • Overload Protection
    • Overload Protection
    • Starters & Enclosed Products
    • Starters & Enclosed Products
    • Motor Controllers & MCCBs
    • Motor Controllers & MCCBs
    • Softstarters
    • Softstarters
    • Circuit Protection
    • Circuit Protection
    • Disconnect Switches
    • Disconnect Switches
    • Rotary Cam Switches
    • Rotary Cam Switches
    • Control Relays & Timers
    • Control Relays & Timers
    • Pilot Devices
    • Pilot Devices
    • Signaling Solutions
    • Signaling Solutions
    • Terminal Blocks
    • Terminal Blocks
    • Power Supplies
    • Power Supplies
    • Electrical Industry Codes
    • Electrical Industry Codes
 

PF Softstarter Auxiliary Contact Configuration

 
 
 
 

Question:

What are the differences between the options Normal, Up-To-Speed and External Bypass when configuring an auxiliary contact on a PF Softstarter? What terminals can be used on an PF Soft Starter to close and indicate that the unit is running?

Answer:

The differences between the options Normal, Up-To-Speed and External Bypass when configuring an auxiliary contact on a PF Soft Starter are described below:

Normal

Contact changes state immediately when a start command is given, it returns to shelf state either when the-stop command is given (coast to stop) or when the motor comes to a stop (braking function). Refer to the instruction manual for Aux. #1 operation.

Up-To-Speed

With Aux. # 1 (NO contact) set to this value the PF remains in control throughout the starting, running, and stopping period. When the PF has detected that the motor has achieved running speed Aux. #1 will close and the internal bypass is turned on. All metering and diagnostics are available and working.

External Bypass

With Aux. # 1 (NO contact) set to this value the PF remains in control throughout the starting and stopping period. When the PF has detected that the motor has achieved running speed Aux. #1 will close. This contact should be used as a start signal to an external bypass. When the external bypass has energized the PF will then revert to a wait state and all SCR firing is inhibited. In addition, the internal PF bypass will NEVER close. All metering and diagnostic functions are suspended, including overload protection, while the PF is in external bypass mode.

Stopping control is still available with external bypass selected. When a stop is initiated the external bypass de-energizes (Aux. # 1 - opens) and the PF begins firing SCR's. At this point metering and diagnostics are available and working.

Terminals 19 and 20 can be used on an PF Soft Starter to close and indicate that the unit is running. This is the default setting (Normal) for Parameter 107 [Aux1 Config].

For additional information please contact your nearest authorized distributor, sales representative, or call our customer service or technical support lines.

Sprecher & Schuh Series PF softstarter load side terminals
 